Refer to the exhibit. An engineer configures the server port on a Cisco Nexus 5000 Series Switch.
The switch connects to an NPV edge switch port. The server fails to send the FC traffic to the fabric. Which action resolves the issue?

정답: A
Refer to the exhibit. An engineer installs and performs the preliminary setup of the new SAN switch and connects the fc1/13 interface to the existing SAN fabric. The engineer notices that the ISL between the switch and the fabric is isolated for a VSAN, and the switch is denied entry into the fabric. Which set of commands permits the switch into the fabric for the VSAN?

정답: A
Refer to the exhibit. customer reports that all Intra-EPG isolation stopped working within a bare- metal tenant. Postman is running on a machine to get information from the APIC in case of orchestration failure. Which action resolves the issue?

정답: A
An engineer must replace a failed memory on a Cisco UCS B-Series Blade Server. After the replacement was done, the server has a "resolve slot" warning. Which server maintenance action resolves the issue?

정답: D
A system administrator connects a Cisco Nexus 2248PQ FEX to a fabric interconnect to expand the ports that are available for connecting Cisco UCS C-Series Rack Servers. In Cisco UCS Manager, the administrator does not see the servers connected to this FEX. Which action should be taken to resolve the issue?

정답: A
Which option is a best practice that should be followed When replacing a CISCO Nexus 5000 Series switch in a vPC topology?

정답: B
설명: (DumpTOP 회원만 볼 수 있음)
A Cisco UCSB-Series Blade Server is configured to boot a VMwareESXi host from an EMC VNX storage array by using a Fibre Channel SAN. The boot order is confirmed to be configured as expected but the server fails to boot from the SAN. Which action reserves the problem?

정답: C
A fabric interconnect fails to start and the console displays the loader prompt. Which two actions resolve the issue? (Choose two.)

정답: A,E
What does this adapter output indicate?
adapter 1/6/1 (fls): 2# lunlist 9
vnic: 9 lifid: 6
- FLOGI State : flogi est (fc_id Oxac0e04)
- PLOGI Sessions
- WWNN 50:0a:09:83:8d:53:43:44 WWPN 50:0a:09:83:8d:53:43:44 fc_id
0x000000
- LUN's configured (SCSI Type, Version, Vendor, Serial No.)
- LUN ID: Ox0000000000000000 access failure
- REPORT LUNs Query Response
- Nameserver Query Response
- WWPN: 54:b1:6a:94:64:3e:73:44

정답: C
A mission-critical server is connected to site A. Connectivity to this server is lost from site B because the MAC route is missing in the OTV VDC of the Nexus 7000 in site B due to MAC aging. Which action allows the flooding of the unknown unicast MAC on the Nexus 7000 in the OTV VDC?

정답: C
설명: (DumpTOP 회원만 볼 수 있음)
Refer to the exhibit. The cURL command fails to complete. Which action resolves the problem?

정답: A
Refer to the exhibit. A network engineer has connected the Nexus switch management port to the Internet using DHCP to allow the Guest shell running on the switch to download Python packages. The engineer can ping google.com successfully from the Nexus switch, but the Guest shell failed to download any Python packages. Which action resolves the problem?

정답: D
Refer to the exhibit. An engineer is performing a health check on ACI.
Which statement about interface Ethernet 1/11 is true?

정답: B
The Cisco Nexus switch is connected to a peer switch that is not running Cisco NX-OS. The switches are connected using port channel and are experiencing packet loss.
Which action should be performed on the Cisco Nexus switch ports to resolve this issue?

정답: A
설명: (DumpTOP 회원만 볼 수 있음)
Refer to the exhibit. The vPC between switch1 and switch2 does not work.
Which two actions resolve the problem? (Choose two.)

정답: D,E
설명: (DumpTOP 회원만 볼 수 있음)
Drag and Drop Question
Drag and drop the Cisco UCS SNMP fault types from the left onto the correct issues on the right.
정답: