최신 H12-425_V2.0 무료덤프 - Huawei HCIP-Data Center Facility Deployment V2.0

How many groups of battery strings that a single UPS5000 can support? (Multiple choice)

정답: A,B,C,D
When a user uses the NETECC APP on the PAD to query the PUE information in the current computer room, he needs to click the () menu.

정답: B
To determine whether the R410A refrigerant meets requirements, compare the internal pressure of the refrigerant with the saturation pressure corresponding to the refrigerant temperature. If the difference between the internal pressure and the saturation pressure is within the range of which of the following, replace the refrigerant?

정답: C
When the Huawei air-cooled air-conditioning compressor is turned on for the first time, the crankcase heating belt needs to be preheated for more than () hours.

정답: C
APM, NR and other UPS products need to be derated at 30 degrees, and UPS5000-E does not need to be below 40 degrees.

정답: A
When the indoor unit is installed higher than the outdoor unit, an oil trap must be installed.

정답: B
The dry contact signal of UPS5000-E does not support the remote emergency stop function.

정답: A
Depth of discharge DOD, indicating the percentage of the battery's rice discharge to the battery's rated capacity.

정답: A
FusionModule800 version 3.0 supports face recognition function.

정답: A
Which of the following description of UPS5000-A is correct? (Multiple choice)

정답: A,B,D
On-demand deployment and avoiding over-investment are the only advantages of Mou Aihua's data center.

정답: A
Which of the following components does not support wireless networking?

정답: D
Which of the following statements about ECC800-Pro features are true?

정답: A
UPS5000-S has the function of adjusting the number of battery cells, which avoids the replacement of the whole group caused by the failure of a single battery, and solves the problem of difficult maintenance of traditional UPS batteries. UPS5000-s supports 30-46 battery adjustable.

정답: A
When there are multiple computer rooms and they are monitored at the same time, the hierarchical deployment of the monitoring system may occur.

정답: B
FusionModule solution can use ECC800 to achieve local monitoring, and use NetEco management system to achieve centralized monitoring of multiple micro-modules.
Then, in the project bidding quotation, which product is the configuration quotation of the ECC800 collector in?

정답: B
Alarms of all devices can be displayed on NETECO, but corresponding alarms cannot be automatically formed into work orders and sent to handlers.

정답: B
Which air supply mode requires reasonable raised floor height?

정답: D
In the parallel steps of the UPS5000-E, the reason for using the EPO status interface is ().

정답: C
The row-level air conditioners (25kw and 42kw) of Huawei FusionModule2000 v3.0 have the refrigerant detection function.

정답: A

우리와 연락하기

문의할 점이 있으시면 메일을 보내오세요. 12시간이내에 답장드리도록 하고 있습니다.

근무시간: ( UTC+9 ) 9:00-24:00
월요일~토요일

서포트: 바로 연락하기